Free calculator

Wall framing calculator

Studs = wall length Γ· stud centres, rounded up, + 1, plus extras at corners, junctions and openings. Plates = wall length Γ— (bottom + top plates). Timber noggings go in rows no more than 1350 mm apart.

Your job

Frame

Top plates

Timber studs at 450 mm, or 600 mm for internal non-loadbearing walls. Double top plates where your frame design calls for them.

Walls

Wall 1

Corners and openings

Enter each wall separately. Their end studs meet at a corner, so each corner adds one more (three in all); a blocking stud per T-junction; and a jamb and trimmer stud each side of every opening.

opening6.00 m at 450 mm centres2.40 m1 nogging row, 1 top plate

The first wall: studs at centres, noggings staggered, and an opening with doubled studs and a lintel (opening drawn door-sized).

Studs

19studs

15 common + 4 extra

Wall length

6.00m

1 wall

Plates

12.0m

Bottom plate + 1 top plate

Noggings

6.0m

Rows no more than 1350 mm apart

Lintels

1

One per opening, sized by your frame designer

The working, with your numbers

  1. 1. Common studs6.00 Γ· 0.450 ↑ + 1= 15
  2. 2. Extra studs0 corners Γ— 1 + 0 junctions + 1 opening Γ— 4= 4
  3. 3. Plates6.00 Γ— 2= 12.0 m
  4. 4. Noggings(height Γ· 1.35 ↑ βˆ’ 1) rows Γ— wall length= 6.0 m
Typed those measurements in by hand?MetreMate measures them straight off your PDF plans. Free to start.

The formula, in plain words

  1. 1Common studs per wall = length Γ· centres, rounded up, + 1. Timber is 450 mm, or 600 mm for internal non-loadbearing walls; steel up to 600 mm.
  2. 2Timber extras: an external corner has three studs (each wall entered separately already ends in one, so a corner adds one), a T-junction a blocking stud, and each opening a jamb and a trimmer stud on either side. Steel: a stud at each corner and junction, and boxed studs beside each opening.
  3. 3Plates = wall length Γ— (1 bottom + 1 or 2 top). Steel track runs top and bottom in 3.0 m lengths.
  4. 4Timber nogging rows = height Γ· 1.35 m, rounded up, βˆ’ 1. Steel rows come from the maker's table: none to 4.4 m lined both sides, one to 3 m lined one side.
  5. 5This counts members only; it doesn't size studs, lintels or bracing.

Worked example

A 6 Γ— 2.4 m timber wall at 450 mm centres with one door opening and a single top plate.

  1. 1.Common studs: 6 Γ· 0.45 = 13.3, so 14 spaces and 15 studs.
  2. 2.The opening adds a jamb and a trimmer stud each side: 19 studs in all, plus one lintel.
  3. 3.Plates: 6 Γ— 2 = 12 m. Noggings: 2.4 Γ· 1.35 = 1.8, so 2 spaces and 1 row: 6 m.

Answer: 19 studs, 12 m of plate, 6 m of nogging and one lintel.

How to measure it

  • Measure each wall's length and the floor-to-ceiling frame height.
  • Count the external corners, T-junctions where walls meet, and the door and window openings.
  • Check the stud centres on the frame drawings: 450 or 600 mm.
  • Loadbearing walls, lintel sizes and bracing come from the frame design, not this count.

Where the numbers come from

Every default in the calculator is a number a supplier or manufacturer publishes. We list the source next to it so you can check.

WhatValueSource
Timber studs at 450 mm centres, or 600 mm for internal non-loadbearing partitions450 mmWoodSolutions, Lightweight Timber Framing Guide (checked 2026-10-01)
Maximum nogging spacing 1350 mm: usually one row for walls up to 2700 mm1,350 mmRMIT BuildRight, Noggings (summarising AS 1684) (checked 2026-10-01)
External corners: three studs fixed with blocking3 studsRMIT BuildRight, Common studs (checked 2026-10-01)
A T-junction gets a blocking stud; openings get full-height jamb studs and trimmer studs on either side1 studWoodSolutions, Lightweight Timber Framing Guide (checked 2026-10-01)
A bottom plate, studs, noggings and one or more top plates1 top plateWoodSolutions, Lightweight Timber Framing Guide (checked 2026-10-01)
Steel studs: maximum spacing 600 mm centres600 mm maxRondo, Steel Stud Drywall Framing System manual (checked 2026-10-01)
Studs beside window and door openings are boxed (doubled)2 boxed studsRondo, Steel Stud Installation Guide (2020) (checked 2026-10-01)
Minimum noggings: lined both sides none to 4.4 m; lined one side 1 row to 3 m, 2 to 6 m, 3 to 8 m1 row to 3 mRondo, Steel Stud Installation Guide (2020) (checked 2026-10-01)
Wall track in 3000 mm lengths; nogging track in 3600 mm lengths3 mRondo, Steel Stud & Track Wall Framing System (checked 2026-10-01)
Steel studs in 2400, 2700, 3000, 3600, 4200, 4800 and (92 mm) 6000 mm lengths2,400 mm shortestRondo, Steel Stud & Track Wall Framing System (checked 2026-10-01)

Manufacturers named here are the source of the number, not a recommendation. Confirm quantities with your supplier.

Frequently asked questions