Batts are 1160 mm long and fit between the framing, so batts = area ÷ (1.16 × frame spacing). A 12 × 9 m ceiling at 450 mm centres is 108 ÷ 0.522 = 207 batts; divide by the batts per pack on the label.
Your job
Where
Batts
Framing centres
R-value
The R-value your home needs depends on its climate zone: check the energy rules for your area.
Pack sizes vary by brand and R-value. Makers don't publish a wastage figure, so add your own if you're cutting around a lot.
Optional
Ask your insulation supplier. The greyed number is an example only and is never used in your result.
One batt fills each space between the framing. Below, the batt's thickness against a 90 mm joist or stud.
Batts
207batts
Add batts per pack to get packs
Area to insulate
108.0m²
1 area
Batt size
430mm wide
× 1160 mm, for 450 mm framing
Thickness
195mm
Typical R4.0; check roof clearance
The working, with your numbers
- 1. Area12.00×9.00= 108.00 m²
- 2. One frame space1.16 m × 0.45 m= 0.522 m²
- 3. Batts108.00 ÷ 0.522, rounded up= 207
Insulation estimate (metremate.com/calculators/insulation-calculator)
- Ceiling 1: 12.00 × 9.00 m
- Area: 108.00 m², 450 mm framing, R4.0
- Batts: 207 (430 × 1,160 mm)
- Estimate only. Check the R-value your climate zone needs and the pack label.
The formula, in plain words
- 1Area = length × width of each ceiling (or length × height of each wall), less windows, doors and spaces left uninsulated.
- 2Each batt fills one frame space: 1.16 m long by the frame spacing (0.45 or 0.6 m). Batts = area ÷ (1.16 × spacing), rounded up.
- 3Packs = batts ÷ batts per pack from the label, rounded up. Pack sizes vary by brand and R-value.
- 4Thickness grows with R-value: a typical R4.0 ceiling batt is about 195 mm, so it stands well above a 90 mm joist.
Worked example
A 12 × 9 m ceiling with joists at 450 mm, R4.0 batts.
- 1.Area: 12 × 9 = 108 m².
- 2.One frame space: 1.16 × 0.45 = 0.522 m².
- 3.Batts: 108 ÷ 0.522 = 206.9, so 207 batts, about 195 mm thick.
Answer: 207 batts (430 × 1160 mm); packs depend on the pack size on the label.
How to measure it
- Measure the ceiling's length and width from inside the roof space, or the room below.
- For walls, measure length and height and add up the doors and windows to take off.
- Check the joist or stud spacing: 450 or 600 mm centres.
- Leave out manholes and the clearance zones round downlights and flues.
Where the numbers come from
Every default in the calculator is a number a supplier or manufacturer publishes. We list the source next to it so you can check.
| What | Value | Source |
|---|---|---|
| Timber-frame batts are 1160 mm long: 430 mm wide for 450 mm centres, 580 mm wide for 600 mm centres (R7.0 ceiling batts 460 and 620 mm) | 1,160 mm long | Knauf Earthwool, Ceiling Batt data sheet (2024) (checked 2026-10-01) |
| Ceiling batt thickness: R3.5 175 mm, R4.0 195 mm, R5.0 210 mm, R6.0 275 mm, R7.0 330 mm | 195 mm at R4.0 | Knauf Earthwool, Ceiling Batt data sheet (2024) (checked 2026-10-01) |
| Wall batts for 90 mm studs: R2.0 at 90 mm | 90 mm at R2.0 | Fletcher Insulation, Pink Batts trade brochure (2026) (checked 2026-10-01) |
| Pack calculator results don't include wastage: discuss with your installer | 0 % | CSR Bradford, pack calculator (checked 2026-10-01) |
Manufacturers named here are the source of the number, not a recommendation. Confirm quantities with your supplier.
Frequently asked questions
Stop typing measurements in by hand
MetreMate measures every wall, floor and roof straight off your PDF plan. Then it hands you the same numbers this calculator asks for.
Try MetreMate freeEstimate only. Check quantities and stocked sizes with your supplier. Free calculators at metremate.com/calculators.